From: Ruslan Ruslichenko Date: Tue, 26 Feb 2013 22:53:24 +0000 (-0400) Subject: staging: omap-thermal: Add print when TSHUT temperature reached X-Git-Url: https://openfabrics.org/gitweb/?a=commitdiff_plain;h=b3bf0e90f05f1addf86ec7237e59b8a096e64e49;p=~shefty%2Frdma-dev.git staging: omap-thermal: Add print when TSHUT temperature reached To indicate that board was shut down due to TSHUT temperature reached it is good to print some information message before shutting down. Signed-off-by: Ruslan Ruslichenko Signed-off-by: Eduardo Valentin Signed-off-by: Greg Kroah-Hartman --- diff --git a/drivers/staging/omap-thermal/omap-bandgap.c b/drivers/staging/omap-thermal/omap-bandgap.c index dcc1448dbf8..35b99158f98 100644 --- a/drivers/staging/omap-thermal/omap-bandgap.c +++ b/drivers/staging/omap-thermal/omap-bandgap.c @@ -133,6 +133,9 @@ static irqreturn_t talert_irq_handler(int irq, void *data) /* This is the Tshut handler. Call it only if HAS(TSHUT) is set */ static irqreturn_t omap_bandgap_tshut_irq_handler(int irq, void *data) { + pr_emerg("%s: TSHUT temperature reached. Needs shut down...\n", + __func__); + orderly_poweroff(true); return IRQ_HANDLED;