-RELEASE: OFED 1.3
-DATE: Feb 2008
+RELEASE: OFED 1.4
+DATE: Dec 2008
===============================================================================
Table of Contents
1. Overview
===============================================================================
-The ibdiag package was enhanced to check more aspects of the network setup,
-including partitions, IPoIB and QoS. Additional major feature is its ability
-to write a topology file of the discovered network. A summary table is provided
-with a list of the executed checks and their results.
+The ibutils package provides a set of diagnostic tools that check the health
+of an InfiniBand fabric.
+Package components:
+ibis: IB interface - A TCL shell that provides interface for sending various
+ MADs on the IB fabric. This is the component that actually accesses
+ the IB Hardware.
+
+ibdm: IB Data Model - A library that provides IB fabric analysis.
+
+ibmgtsim: An IB fabric simulator. Useful for developing IB tools.
+
+ibdiag: This package provides 3 tools which provide the user interface
+ to activate the above functionality:
+ - ibdiagnet: Performs various quality and health checks on the IB
+ fabric.
+ - ibdiagpath: Performs various fabric quality and health checks on
+ the given links and nodes in a specific path.
+ - ibdiagui: A GUI wrapper for the above tools.
===============================================================================
2. New Features
===============================================================================
-The following new checks were added to the tools:
-
-ibdiagnet new features:
------------------------
-+ Partitions Check:
- - Validate all leaf switch ports (connected to a host) which enforce
- partitions are not blocking partitions set on the host ports they
- are connected to.
- - Report for each partition the member hosts and their membership status.
- Full membership allows hosts to communicate to any other member.
- Partial membership allows communication with full members only.
- The new report file is named ibdiagnet.pkey.
-
-+ IPoIB Subnets Check:
- - The IPoIB subnets and their properties are reported.
- - For each group all the host ports that are part of the partition are
- checked to have a high enough communication rate to be part of the group
- (warn if not).
- - If all the group members can use a communication rate higher then the group
- rate a warning is produced as the subnet uses a suboptimal rate.
-
-Other changes:
-+ The multicast groups report was enhanced to provide the details of each
- group and the members list is provided in a new report file: ibdiagnet.mcgs.
-
-+ A new flag, -wt <file-name>, was added. ibdiagnet, with the new option,
- writes out a discovered topology file by the provided file-name and
- the required new IBNL files into an output directory named ibdiag_ibnl.
- This new feature allows you to capture the current state of the fabric
- and later compare to it. Such the features provided by the "Topology
- Matching" check becomes available. These feature include recognizing
- changes in connections, speed and width.
-
-+ Load subnet database from file:
- Ibdiagnet dumps its internal database, which contains the subnet structure,
- to a file (/tmp/ibdiagnet.db by default). This file can be loaded in later
- ibdiagnet runs (using the -load_db <db file> option). When this option is set,
- ibdiagnet loads the subnet data from the file and skips the discovery stage.
- Using this option can save the subnet discovery time for large cluster.
- Note: Some if ibdiagnet checks would not be performed when the -load_db
- option is set. These checks are:
- - Duplicated guids.
- - Zero guids.
- - Links in INIT state.
- - SMs status.
-
- + A new flag, -skip <skip-option(s)>, was added. When this flag is specified,
- ibdiagnet skips the given check. One or more space separated values can be
- specified.
- Available skip options: dup_guids, zero_guids, pm, logical_state, part,
- ipoib. The -skip flag can be used in order to run only specific checks, or
- to reduce ibdiagnet run time.
-
-ibdiagpath new features:
-------------------------
-+ Partitions Check:
- - The list of partitions of source and destination ports is reported.
- - A check for which partitions are common to the source, destination and
- every port on the path (if enforcing partitions) is calculated and
- reported. A warning is provided if a source partition is blocked by
- a port on the path.
- An error is provided in there are no common partitions for the path.
-
-+ IPoIB Subnets Check:
- - The IPoIB subnets available for the path and reported.
- - If the source or destination ports are members in partitions which have
- an IPoIB group and for some reason can not join the group a warning is
- provided.
-
-+ QoS Check:
- With the introduction of QoS, the following new issues might arise from
- improper setup of the fabric:
- - VL Arbitration Tables might use VLs which are higher then the currently
- supported maximal VL on the port. A warning is provided for such cases.
- - VL Arbitration Tables might "block" a VL by setting its weight to zero.
- A warning is provided for these cases
- - SLs (service levels) might be mapped to VLs which are blocked by the
- two above rules. In such case these SLs can not be used by the path.
- A report including the set of "valid" SLs for the path is provided.
- - If there are no "valid" SLs an error is provided since the source and
- destination ports can not communicate.
-
-Common changes to all tools:
-----------------------------
-A summary table of all the checks performed and their total number of errors and
-warnings was added to the tools standard output.
+
+* Mellanox InfiniScaleIV support:
+ - Support switches with port count > 32
+ - Added ibnl (IB network) files for MTS3600 and MTS3610 InfiniScaleIV based switch systems.
+
+* IBDM QoS Credit Loop check:
+ This check now considers SL/VL when looking for credit loops.
+ This check can be activated by running "ibdiagnet -r"
+
+* ibdiagnet: Added -csv flag, which generated a set of Comma Separated Values
+ files, which contains data about the fabric. Generated files:
+ inv_csv - Lists the ports found in the fabric
+ links_csv - Lists the ports connections in the fabric
+ pm_csv - Lists port counters in csv format
+ err_csv - Lists errors found during the run
+
+* ibmgtsim: Add basic M_Key mechanism simulation
===============================================================================
3. Major Bugs Fixed
===============================================================================
-+ Fabrics Qualities report is now available in the main log file (and not only
- in the standard output
+* ibdm: Support 2 port switches in a loaded LST file.
+
+* ibis: fix some buffer overrun bugs with long node description.
+
+* Installation: Ibdiagui requires tcl/tk 8.4 or 8.5 (was only 8.4). This allows
+ installation on Fedora Core 9.
+
+* ibdiagnet: Fixed -pm flag caused a crash on back to back (no switch) setup.
+
+* ibdiagnet: Do not query port counters when local port is in INIT state.
===============================================================================
4. Known Issues
===============================================================================
-- Ibdiagnet tries to query port counters for ports in INIT state. In this
- case, run time would be longer and an error message for each port would be
- printed to screen.
- Workaround:
- * Use "-skip pm" option if links in INIT state are found.
- * Run opensm to activate the links.
-
-- A failure in IPoIB check may cause ibdiagnet to exit, without printing the
- summary report.
-
- Ibdiagnet "-wt" option may generate a bad topology file when running on a
cluster that contains complex switch systems.
-
--- /dev/null
+ Open Fabrics InfiniBand Diagnostic Utilities
+ --------------------------------------------
+
+*******************************************************************************
+RELEASE: OFED 1.4
+DATE: Dec 2008
+
+===============================================================================
+Table of Contents
+===============================================================================
+1. Overview
+2. New features
+3. Major Bugs Fixed
+4. Known Issues
+
+===============================================================================
+1. Overview
+===============================================================================
+
+ uhis package contains a burning tool and diagnostic tools for Mellanox
+ manufactured cards. It also provides access to the relevant source
+ code. Please see the file LICENSE for licensing details.
+
+2) Package Contents
+ a) mstflint source code
+ b) mflash lib
+ This lib provides Flash access through Mellanox HCAs.
+ c) mtcr lib (implemented in mtcr.h file)
+ This lib enables access to HCA hardware registers.
+ d) mstregdump utility
+ This utility dumps hardware registers from Mellanox hardware
+ for later analysis by Mellanox.
+ e) mstvpd
+ This utility dumps the on-card VPD.
+ f) hca_self_test.ofed
+ This scripts checks the status of software, firmware and hardware
+ of the HCAs installed on the local host.
+
+===============================================================================
+2. New Features
+===============================================================================
+
+* Mellanox InfiniScaleIV switch support.
+ Mstflint and the mflash lib support burning of this switch device.
+ mstregdump can dump InfiniScaleIV registers
+
+* Added hca_self_test.ofed tool to the package.
+ See file hca_self_test.readme included in the package for details.
+
+===============================================================================
+3. Major Bugs Fixed
+===============================================================================
+
+* Fixed: Mstregdump on ConnectX devices cause the device to hang
+
+===============================================================================
+4. Known Issues
+===============================================================================
+
+